7 2.1 PDP-7 Instruction Test (Maindec 701)
9 The diagnostic must be boot loaded, as it jumps dynamically out
10 of the RIM load process into its own loader.
12 At start, set SR<1:16> to a non-zero value. The diagnostic
13 executes four HLT's as part of initial tests and then runs to
14 completion. Normal HLT is at 2623 (PC = 2624).
16 sim> att -e ptr digital-7-54-m-rim.bin
19 HALT instruction, PC: 17670 (AND 17727)
20 sim> d sr 4 ; any even value between 2 and 377776
23 HALT instruction, PC: 00171 (CML CMA)
29 HALT instruction, PC: 00173 (SPA)
35 HALT instruction, PC: 00176 (SPA)
41 HALT instruction, PC: 00201 (LAC 4116)
47 HALT instruction, PC: 02624 (JMP 201)
53 Operating Instructions, PDP-15 diagnostics
55 MAINDEC-15-D0A1-PH Instruction test 1
59 Breakpoint: 7274 for one pass
61 MAINDEC-15-D0A2-PH Instruction test 1A
65 Breakpoint: 4437 for one pass
67 MAINDEC-15-D0AA-PB Index register test
69 Read in: 17700 (ignored, binary tape)
71 Halts: at 214, set BANKM = 0
72 Runs to: prints END at end of pass
74 MAINDEC-15-D0BB-PH Instruction test 2
78 SR: 1 to run clock test
79 Breakpoint: 6403 for one pass
81 MAINDEC-15-D0CA-PH Memory address test
85 Breakpoint: 7577 for one pass
87 MAINDEC-15-D0EA-PH JMP-Y interrupt test
91 Breakpoint: 7551 for one pass
93 MAINDEC-15-D0FA-PH JMS-Y interrupt test
97 Breakpoint: 7577 for one pass
99 MAINDEC-15-D0KA-PH ISZ test
103 Breakpoint: 7704 for one pass
105 MAINDEC-15-D1CD-PB Extended memory test
107 Read in: 200 (ignored, binary tape)
109 Halts after printout, set SR = 30000
110 Breakpoint: 563 for one pass