maindec: Added the usual collection, with intact symlinks
[pdp8.git] / sw / maindec / rk8e / dhrka / maindec-08-dhrka-be.txt
diff --git a/sw/maindec/rk8e/dhrka/maindec-08-dhrka-be.txt b/sw/maindec/rk8e/dhrka/maindec-08-dhrka-be.txt
new file mode 100644 (file)
index 0000000..fdfeaef
--- /dev/null
@@ -0,0 +1 @@
+RK8-E Diskless Control Test\r\r\rMAINDEC-08-DHRKA-E-D (Documentation)\rMAINDEC-08-DHRKA-B-PB (Paper Tape)\r\r\rTest   Addr.   PC      Description\r----------------------------------------------------------------------------------------------\r0    0226            Check if disk motor is off. Status 2200 expected.\r1     0235\r2  0242\r3  0250\r4  0256\r5  0272\r6  0305\r7  0314\r8  0323\r9  0334            Check if DCLR clears AC, try all AC combinations\r10     0343    0363\r11 0365\r12 0410\r13 0424\r13 0441\r15 0454    0505    Verify that DLAG loads sector and surface\r16    0507\r17 0537            Verify that disk address can be loaded and shifted into ldb\r18  0561\r19 0604\r20 0616\r21 0633    0645    Verify that DCLR(01) does not clear surface and sector\r22       0647\r23 0673\r24 0720\r25 0742    0765    Verify that DCLR(!=10) does not affect CRC using DLAG and DLDC\r26       0767    1026    Is CRC not affected by DLDC,DSKP,DRST,DLCA and read buffer?\r27  1030    1045    Verify that write lock inhibits load address when set\r28        1047    1075    DCLR,DLCA,DRST,DLDC,DSKP and read buffer affect sect & surf?\r29 1077    1130    Verify that command register is not affected by DLCR,... \r30    1132    1150    Verify that recalibrate inhibits load command on DLDC\r31        1152    1171    Verify that recalibrate inhibits load disk address on DLAG\r32   1173\r33\r34\r35\r36\r37\r38\r39\r40\r41 1526\r42\r43\r44\r45        1615    1650\r46\r47\r48\r49        2000    2033    Verify that Data Request Late occurs when ldb is empty \r50      2035    2075\r51 2077    2115    Verify that DSKP skips on DRL error\r52\r53       2134    2157\r54 2200    2226\r55 2253    2230    Verify that recalibrate does set drive status error\r56  2270    2255\r57 2306    2272\r58\r59\r60\r61\r62     2444    2466    Does maintenance mode inhibit drive status error skip?\r63       2470    2526    Does recalibrate, then DCLR set control busy and status error?\r64       2530    2566    Does recalibrate, then DRL set DRL, status error and done?\r65   2600    2634    Does recalibrate, then DLCA set control busy and status error?\r66       2636    2655\r67 2657    2675 \r68        2677    2716    Verify that skip occurs on control busy error\r69        2720    2751    Verify that DCLR(0) clears all of status register\r70    2753    2775    Verify that interrupt occurs on control busy error\r71   2777    3042    Verify that read buffer,DCLR,DRST,DLAG,DSKP not affect status\r72        3044    3116    Does word count overflow after 256 12-bit-shifts and set done?\r73\r74    3271    3341    Does half block flag in command register work?\r75\r76\r77 3443    3471    Verify data break at loc. 0 of current field with "write"\r78\r79\r80\r81\r82\r83\r84  3737    3777    Verify current address increments from 7777 to 0 on "write"\r85  4001    4052    Verify current address increments from 200 to TST85 on "write"\r86       4054    4153    Is write inhibit set after 256 breaks and cleared by DLAG?\r87   4200    4272    Is write inhibit set after 128 breaks and cleared by DLAG?\r88   4274    4321    Verify "read" data break at 0000 and 7777\r89\r90\r91\r92\r93\r94                     Verify that command 2 causes a "read" data break\r95                     Verify that command 3 causes a "read" data break\r96     -       -       -\r97    5000    5027    Verify that command 6 causes a "read" data break\r98                     Verify that command 7 causes a "read" data break\r99     5063    5127    Verify that all data buffers can be full by "read" data break\r100\r101\r102\r103\r104\r105
\ No newline at end of file